The SVA 90 comes as a handy, three-channel vibration analyzer with speed unit that allows for the evaluating of machinery condition and rolling–element bearings with characteristic overall values. This instrument will help you to prevent costly downtime.
The Smart VibroAnalyzer 90 is a small portable unit focused for data collection. The SVA 90 key features included are Speed Detection, Meter Mode, Diagnostic, Stroboscope, and Diagnostic Center Basic.

SVA 90 Base Kit:

Meter Mode
This module includes the following basic vibration measurements:
  • Overall vibration
  • Provides a traffic light display of vibration values based on pre-setup limits. The color indication is according to ISO 10816 standards.
  • Overall (RMS) and Peak values are displaced with the following frequency ranges: Velocity (10 Hz – 1000 Hz) or Acceleration (0.5 kHz -25.6 kHz)
  • FFT Spectrum
    In mm/s (RMS) with 3 maximum peaks (2 Hz – 200 Hz)
  • Displacement values
    Uses the following frequency range of (2 Hz – 100 Hz)
  • Time Signal
  • Used for roller bearings (0.5 kHz -25.6 kHz)
  • Vibration in RMS for gearboxes/bearings in the following frequency ranges (0.5 kHz -1.5 kHz), (1.5 kHz -5 kHz), & (5 kHz -25.6 kHz)
  • Temperature
    Displayed in colored ranges using IR temperature sensor

Diagnostic
This module is an expert system for automatic detection of possible machine faults. Displays the following faults:
  • Overall machine condition
  • Overall bearing condition
  • Severity of unbalance fault
  • Severity of mechanical looseness
  • Severity of misalignment
  • Displays via text if the found condition is good or severity of fault or provides a velocity spectrum displayed on the bottom of the screen.

Stroboscope
This module visually “freezes” the machine movement and checks its rotating parts

Diagnostic Center Basic
This software allows for connection of the SVA 90 to the PC for Report Generation.



SVA 90 Software Options:

Tracking
This module allows the user to set up a coast down or runup measurement.
  • The measurements can be taken based on multiple situations such as by speed change, time change, as soon as possible, etc.
  • This feature helps the user see where resonances in their machine are located allowing for additional analysis or balancing to be performed.

Data Collector
This module is used for day-to-day data collection of your factory machinery. Simply create your route tree with measurement points using the Diagnostic Center Standard software and take the measurements regularly. Transfer this collected data back to the Diagnostic Center to analyze the data and trends.
  • Unlimited number of routes
  • Up to 12 measurements per point
  • Up to 3 vibration measuring points, plus speed reference (Simultaneously measured)
  • Data review on site possible
  • Off route measurements are possible
  • Diagnostic Center Standard
  • Customized Reports via PC

Analyzer
This module allows the user to select the type of measurement from simple overall values to detailed FFT’s and time wave forms. In addition, the user can perform more advanced measurements with proximity probes such as orbits.
  • Real-time FFT
  • Demod/envelope analysis
  • ACM– low speed bearing analysis
  • Order Analysis
  • Orbit Measurement
  • User Band Pass Analysis
  • Frequency Range: 0.5 Hz - 25 kHz (64 kHz sampling)
  • FFT Resolution: Min: 100 lines, Max: 25,600 Lines
  • Fully simultaneous for 3 channels
  • Crest Readings
  • Time signal measurements
  • Phase Shift
  • DC Measurements
  • Centerline Measurements
  • Smax
  • Overall Measurements

Field Balancing
This module allows for balancing equipment in situ, both in the field and during final assembly, providing a quality product.
  • Multiple balancing types such as Polar (0-360 degrees), component, and fixed weights
  • Flexible Visualization of balancing: polar plot and table overview
  • Optimizing the final vibration level at the two bearings supports in an early stage while balancing in a single plane
  • Allows for Rotor setting to calculate balance quality according to ISO 1940

Ultrasound
This module uses a microphone (sold separately) to allow for the measurement of sound inaudible to the human ear.
  • Typical applications that benefit from the use of ultrasound measurements are air leak detection, electrical arcing, or early bearing fault detection.

Recorder
This module is a unique measurement mode allowing you to “record” the raw signal from the sensor i.e. the raw signal from the machine.
  • The Recorder allows you to then post-process the signal later on the unit.
  • The user can perform the post-processing on the same raw data multiple times.

Diagnostic Center Standard
The Upgrade from Basic to Standard allows for additional cursor functions when analyzing the data on the PC. The Standard software also allows for the creation of Routes and is needed when the Data Collection module is added.

Diagnostic Center Pro
The upgrade to the Pro version of the software allows for the management of custom report templates and the use of the bearing and system database.
{{ this.trans('product.manufacturer') }} {{ $parent.product.manufacturer }}
{{ this.trans('product.product_group') }} {{ $parent.product.producttype }} | {{ $parent.product.category.title }} {{ $parent.product.category.title }}
{{ this.trans('product.productname') }}
{{ this.trans('product.itemnumber') }} {{ $parent.product.itemnumber }}
{{ this.trans('product.techdata') }}
{{ key }}
{{ key }} {{ value }}
{{ this.trans('product.techinfo') }}
{{ key }} {{ value }}
Description
Product images

Login or register now and enjoy all the benefits of a community!

To get the whole functionality of IndustryArena Forum you need to login or register. This process is absolutely free.

Password forgotten?
Contact request
Guest Photo
Your message
The controller within the meaning of Art. 4(7) GDPR is: IndustryArena GmbH, Schneiderstr. 6, 40764 Langenfeld, Germany.
You may reach our data protection officer under [email protected].

Purpose of processing
We process your personal data concerning the use of the contact form and the communication with the company of the newsroom as well as the transmission of your data to this company in accordance to Art. 6 (1a) GDPR. This constitutes a legitimate interest for us in accordance to Art. 6 (1f) GDPR.

Recipient of the data
Within our organization, those units gain access to your data, which are necessary to fulfil the above purposes.
Personal data will only be transmitted to third parties if this is necessary for the aforementioned purposes or if another legal basis exists. If necessary, we conclude the corresponding data protection agreements with third parties, in particular pursuant to Art. 28 GDPR.

Data storing
Your data will be transmitted to the company of the newsroom for further processing. The period of storing is the duration of the processing of your request by the respective company.

Select contact person

Newsroom Logo

Design options

  • Title text color:
  • Content background:
  • Content text color:
  • Navigation background:
  • Tab text color:
  • Active tab text color:
  • Link text color:
  • Active link text color:
  • Background image Background color:

    How do you want to position the background-image?

    Please note: Banners and skyscrapers are only saved for the current language. For other languages, change the language using the button at the top right.

    Set the link for the background image

  • Design options only available for Premium Members

    To the membership page
  • Banner

    How do you like to align the banner?

    Please note: Banners and skyscrapers are only saved for the current language. For other languages, change the language using the button at the top right.

    Set the link for the banner

  • Skyscraper

    Set the link for the skyscraper

Please note:

Banners and skyscrapers are only saved for the current language. For other languages, change the language using the button at the top right.